Application

Sensor mount

A sensor mount is an accuracy component in a measurement chain. Its own error — position, tilt, thermal drift, vibration — gets added to every reading the sensor makes.

Send a drawing

Three errors that come from the mount

Position: the sensor is not where the drawing says, so every reading is offset. Tilt: a mount face 0.1 mm out of square over 20 mm tilts the sensor 0.3°, which for a distance sensor is a large error. Thermal drift: an aluminum mount expands 23 µm/m/°C, so a 100 mm mount moves 2.3 µm per degree.

FeatureTypical requirementEffect if missed
Mount position0.05 mmConstant offset in every reading
Face squareness0.05 mmTilt, especially for optical sensors
Thermal expansionMaterial choiceDrift with temperature
Mount stiffnessPer applicationVibration in the signal
Surface flatness0.05 mmSensor body distortion

Material and thermal drift

Aluminum is light and machinable, and it moves 23 µm/m/°C. Steel moves about 11, invar about 1. For a sensor that has to hold a position across temperature, that difference is the design.

The usual compromise is aluminum with a design that is insensitive to expansion — slots rather than round holes, or a kinematic mount that allows movement without stress.

Vibration and isolation

A stiff mount transmits vibration straight into the sensor. Sometimes that is what you want — measuring the machine, not the world. Sometimes it is not, and an elastomer isolator or a mass is added.

That is a design decision the machinist cannot make. Say what the sensor is measuring and the mount follows.

Mount types

How the mount attaches decides how much of the machine’s error reaches the sensor. A bolted mount transmits everything; a kinematic mount repeats without stress; an isolated mount filters vibration.

The choice depends on what the sensor measures. Measuring the machine needs a stiff mount; measuring the world needs isolation.

Mount typeRepeatabilityUse
Bolted flatDepends on the facesGeneral
Kinematic (3 points)Very highRemovable, repeatable
SlottedOne axis freeThermal expansion relief
IsolatedLow transmissionVibration-sensitive sensors
AdjustableSet onceAlignment during commissioning

FAQ

Why does my sensor reading drift?
Thermal expansion of the mount, or the mount face is not square and the tilt changes with temperature.
What material for a stable mount?
Steel or invar for thermal stability; aluminum for weight and cost.
How accurate should the mount be?
0.05 mm position and squareness is typical. Optical sensors need more attention to tilt than to position.

Have a drawing to review?

Send the model, the revision and the quantity. You get a written review of the open items with the price.