Inspection fixture
A fixture is a measuring instrument. It holds a part in a defined position, and if that position is not repeatable to a fraction of the tolerance being checked, the measurement is noise.
Send a drawingRepeatability is the whole requirement
A fixture locates a part on a datum face and two features. The repeatability of that location — how much the part moves between loadings — has to be a small fraction of the tolerance being inspected, usually 10-20%.
That makes the fixture tolerances tighter than the part’s: a 0.05 mm part tolerance needs a fixture that repeats to 0.01 mm.
| Feature | Typical requirement | Effect if missed |
|---|---|---|
| Datum face flatness | 0.01-0.02 mm | Part rocks |
| Locating bore position | 0.01 mm | Position error in the measurement |
| Locator wear surface | Hardened or coated | Repeatability drifts |
| Clamp force | Controlled | Part distortion while measured |
| Access for probe | Clear | Features cannot be reached |
Wear is the hidden failure
Locating pins and datum faces wear. After a few thousand loadings a soft aluminum fixture no longer repeats, and nobody notices because the fixture still looks fine.
Hard anodize, hardened steel inserts or replaceable locators solve it. Replaceable pins are the cheapest long-term design: the fixture body stays, the pins are swapped.
Design and inspection
The fixture is usually machined to a drawing that the customer’s metrology team approves. It is then verified on the CMM against that drawing, and it should be re-verified periodically.
Clamping is part of the design: a clamp that distorts the part produces a measurement of the distorted part, which is worse than no measurement.
Fixture types
The fixture type follows the inspection: a CMM fixture holds the part for probing, a functional gauge checks one feature fast, and a leak test fixture seals the part.
Each has a different tolerance requirement. A CMM fixture needs position repeatability; a go/no-go gauge needs the single feature to be right.
| Type | Holds | Requirement |
|---|---|---|
| CMM fixture | Part for probing | Datum repeatability 0.01 mm |
| Go / no-go gauge | One feature | Gauge tolerance 10% of part |
| Leak test fixture | Sealed part | Seal face and clamp force |
| Assembly fixture | Parts in position | Location repeatability |
| Welding fixture | Parts aligned | Heat resistance, distortion control |
FAQ
- What tolerance does a fixture need?
- Roughly 10-20% of the tolerance it inspects. A 0.05 mm part needs a 0.01 mm fixture.
- Why does my fixture stop repeating?
- Locator wear. Use hardened inserts or replaceable pins.
- Can you make a fixture from a customer drawing?
- Yes. Send the drawing plus the part model and the datum scheme.
Have a drawing to review?
Send the model, the revision and the quantity. You get a written review of the open items with the price.